Optional reclaimed water ID
OPERATING SPECIFICATIONS
Flow:
– ICV-101G: 0.06 to 9 m3/ hr; 0.4 to 150 I/min
– ICV-151G: 4 to 34 m3/ hr; 75 to 568 I/min
– ICV-201G: 9 to 45 m3/ hr; 150 to 757I/min
– ICV-301: 34 to 68 m3/ hr; 570 to 1,135I/min
Recommended pressure range: 1.5 to 15.0 bar; 150 to 1500 kPa
SOLENOID SPECIFICATIONS
24 VAC solenoid
- 350 mA inrush, 190 mA holding, 60 Hz
- 370 mA inrush, 210 mA holding, 50 Hz
ICV-101G
Inlet Diameter: 1″ (25 mm) Height: 14cm
Length: 12 cm Width: 10cm
ICV-201G
Inlet Diameter: 2″ (50 mm) Height: 18cm
Length: 17 cm Width: 14cm
ICV-151G
Inlet Diameter: 1½” (40 mm) Height: 18cm
Length: 17 cm Width: 14cm
ICV-301
Inlet Diameter: 3″ (80 mm)
Height: 27 cm
Length: 22 cm
Width: 19 cm
FACTORY INSTALLED OPTIONS
- DC latching solenoid
- Filter Sentry
USER INSTALLED OPTIONS
Solenoid conduit cover (P/N 464322) DC latching solenoid (P/N 458200) Accu-Sync pressure regulator
Reclaimed water ID handle for ICV101, 151, 201 (P/N 561205)
and 301 (P/N 515005)
Reclaimed water ID Tag for all ICV valves (P/N 700392) (Included on Filter Sentry Models)
► = Advanced Feature descriptions on page 80